Stability for life

CONCEPT
STABILITY FOR LIFE

Despite the excellent longevity of total knee arthroplasty,
many patients continue to experience functional deficits after surgery.


Patient expectations are not as well fulfilled by TKA as by total hip replacement with fewer knee patients achieving a “forgotten joint” replacement.  Studies show that around 20% of TKA patients are not satisfied[1, 2, 3].  Excessive A/P motion may result in anterior knee pain and continued swelling.  In many P/S designs, the stabilising mechanism only engages after 70-80° of flexion leaving the knee vulnerable to A/P instability during the most commonly encountered functional activities[4].

PATIENT SATISFACTION

In a study in which patients had a conventional CR or PS in one knee and a medially stabilised device in the other, 76% preferred the knee with the “ball in socket” medial compartment[5]. Patients reported:

  • It feels more normal
  • It is stronger when ascending/descending stairs
  • It has superior single-leg weight bearing
  • It  feels more stable during flexion and overall
  • There are fewer clunks, pops and clicks

GMK SPHERE

Based on the knee anatomy and kinematic studies performed by Prof. Michael Freeman and Prof. Vera Pinskerova[6], the GMK Sphere is an innovative total knee implant designed to deliver maximum functional stability with the goal of increasing TKA patient satisfaction during activities of daily living and decreasing post-operative knee pain.
GMK Sphere is also available with SensiTiN, a ceramic-like coating designed to reduce the release of metal ions from the implant. [12]

RESPONSIBLE INNOVATION

Medacta is committed to providing innovative and safe solutions for patients with an evidence-based approach.
GMK Sphere was tested over 3 years prior to launch through an intensive evaluation program including in vitro and in vivo trials and
Laboratory tests[8,10,11,14].

PRODUCT RANGE

FEMORAL COMPONENT

13 sizes
Anatomical: left and right
Cemented: 0.5 mm deep pockets
Material: Cobalt-Chrome (Co-Cr-Mo ISO 5832-4)

Material: Cobalt-Chrome (Co-Cr-Mo ISO 5832-4) + SensiTiN coating

GMK SPHERE FIXED INLAY

6 sizes
Anatomical: left and right
7 levels of thickness (10, 11, 12, 13, 14, 17, 20 mm)
Machined Ultra High Molecular Weight Polyethylene (UHMWPE ISO 5834-2)

 

E-CROSS (Vitamin E Highly Crosslinked UHMWPE)

GMK SPHERE CR FIXED INLAY

6 sizes
Anatomical: left and right
5 levels of thickness (10, 11, 12, 13, 14 mm)
Machined Ultra High Molecular Weight Polyethylene (UHMWPE ISO 5834-2)

 

E-CROSS (Vitamin E Highly Crosslinked UHMWPE)

TIBIAL COMPONENT

6 sizes
Anatomical: left and right
Cemented: 0.5 mm deep pockets
Material: Cobalt-Chrome (Co-Cr-Mo ISO 5832-4) 

Material: Cobalt-Chrome (Co-Cr-Mo ISO 5832-4) + SensiTiN coating

RESURFACING PATELLA

Anatomical shape
4 sizes
Machined Ultra High Molecular Weight Polyethylene (UHMWPE ISO 5834-2)
Cemented
Three fixation pegs

 

E-CROSS (Vitamin E Highly Crosslinked UHMWPE)

INSET PATELLA

Symmetrical shape
4 sizes
Machined Ultra High Molecular Weight Polyethylene (UHMWPE ISO 5834-2)
Cemented
 

TIBIAL EXTENSION STEM

Diameter x length: 11x 30 mm and 11 x 65 mm
Cemented

TECHNICAL DATA

STABILITY

GMK Sphere features a fully congruent medial compartment providing:

  1. High stability throughout the range of motion[7,10,11]
  2. No paradoxical motion between femur and tibia[7,10,11]
  3. No implant-related “mid-flexion” instability[7,10,11]

NATURAL PATELLAR TRACKING

GMK Sphere replicates natural lateralised patella tracking to reduce patello femoral joint pressure and address anterior knee pain[8,9]:

  1. Trochlea groove lateralised by 2 mm to enable natural patella tracking.[9]
  2. Flattened medial trochlear wall prevents patello-femoral overstuffing minimising retinacular tension.[8]
  3. Anatomic patellar implant with medialised dome allows for optimal bony coverage with reduced soft tissue tension, improved stability and contact area.[12]

ANATOMICAL FIT

Extensive anthropometric research on a unique global database containing more than 15,000 CT and MRI scans of knees validated the[12]:

  1. Range of 13 femoral sizes with 2 mm increments that best fit a broad spectrum of anatomic profiles
  2. Anatomically shaped tibial baseplate
  3. Range of inserts with 1 mm increments
  4. The combination of 13 femoral sizes and inserts with 1 mm increments allows the surgeon to “fine tune” ligament balance and improve stability throughout the range of motion.

PATIENT-SPECIFIC KINEMATICS

GMK Sphere accommodates the best pattern of kinematic motion for each patient rather than imposing an assumed “norm”[11]. This is achieved with:

  1. “Ball in socket” stability throughout the range of motion in the medial compartment[7,10,11]
  2. Freedom of movement in the lateral compartment[10,11]

MINIMISED WEAR RATE

GMK Sphere maximises the femoro-tibial contact area to minimise polyethylene wear.


 

REFERENCES

[1] Bourne RB et al. “Patients satisfaction after total knee arthroplasty: who is satisfied and who is not?” Clin Orthop Relat Res, 2010.
[2] Tippett SR et al. “Collecting Data with Palm Technology: Comparing Preoperative Expectations and Postoperative Satisfaction in Patients Undergoing Total Knee Arthroplasty “ J Bone Joint Surg Am. 2010.
[3] Behrend et al.” The “Forgotten Joint” as the Ultimate Goal in Joint Arthroplasty”, The Journal of Arthroplasty vol 27, n 3, 2012.
[4] Blaha D “The Rationale for a Total Knee Implant That Confers Anteroposterior Stability Throughout Range of Motion” The Journal of Arthroplasty Vol. 19 No. 4 Suppl. 1 2004.
[5] Pritchett JW “Patients Prefer A Bicruciate-Retaining or the Medial Pivot Total Knee Prosthesis”, The Journal of Arthroplasty, 2011.
[6] Freeman MAR, Pinskerova V “The movement of the normal tibio-femoral joint”, J Biomech. 2005 Feb;38(2):197-208.
[7] Hossain F et al. “Knee arthroplasty with a medially conforming ball-and-socket tibiofemoral articulation provides better function”, Clin Orthop Relat Res. 2011 Jan;469(1):55-63.
[8] Jansson V et al, “Kinematics and contact patterns before and after TKA: an in vitro comparison of GMK PS vs. GMK Sphere”, Podium presentation at DKOU 2014, October 28-31 2014.
[9] Meijerink HJ et al, “The trochlea is medialized by total knee arthroplasty. An intraoperative assessment in 61 patients”. Acta Orthopaedica, 2007.
[10] Morra EA, Greenwald AS “Simulated kinematic performance of The GMK-Sphere Total Knee Design During A Stand to Squat Activity”, Study Report 2013.
[11] Banks S et al, “In Vivo Kinematics of a Medially Conforming & Rotationally Unconstrained TKA Design”, Podium presentation at the 27th Annual Meeting of the International Society for Technology in Arthroplasty, Kyoto, Japan, September 25-27, 2014.
[12] Data on file: Medacta.
[13] Haider H, Kaddick C, “Wear of Mobile Bearing Knees: Is It Necessarily Less?”, Journal of ASTM International, 2012.
[14] Field R et al, “Preliminary results of GMK Sphere”. 7th M.O.R.E. International Symposium, Proceedings. Distributed with The Bone & Joint Journal, June 2014 issue.

SYNERGY

MYKNEE

MyKnee is a patient-specific cutting block, allowing the surgeon to realize his pre-operative 3D planning, based on CT or MRI images of the patient’s knee.
This innovative concept combines different features giving potential benefits to both the surgeon and to the patient.

GMK REVISION SOLUTIONS

Medacta's Knee Revision portfolio consists of a wide range of implant options and combinations to address ligament instability and bone defects and allows the surgeon to find the best solution for each patient.

Featuring modular instrument and implant solutions, Medacta’s products deliver the flexibility to accommodate the interoperative demands even in the most challenging surgical scenarios.

M.O.R.E. EDUCATION KNEE PROGRAM

Resources
For additional resources please visit resources.medacta.com
Related products